I have 400w of
Solar and
Victron gear installed and a van blitz
battery master so have no problems keeping the batteries charged,
My question was has anybody who is using a Voltronic MPPT dual regulator have it act the same as a
battery master at night and provide a trickle charge to the Starter
battery with EHU connected or with out
Cheers
BTW, the way a trickle charger/
battery maintainer is supposed to work by default is to provide a trickle/maintenance charge to an auxiliary
battery (starter typically) when the main
battery is charging and effectively diverting a small part of that charge. And if the main
battery is not being charged, there should be no trickle to the starter
battery
The older designs of maintainer, such as the vanbitz
Battery Master work on a very simple voltage differential and if you fit one of these to a Lithium main
battery, it will be probably permanently on regardless of any charging state as the general voltage of a Lithium
battery is too high for switch off.
The
Battery Master (and most other Trickle Chargers such as the Votronic, Sterling and CBE ones as examples) should not really be fitted to a Lithium setup. There are a couple of Lithium compatible units, and which have been designed with Lithium in mind, and the primary example is the Ablemail AMT-12, which will work with any
battery type on the market and also with both Smart and Standard Alternators, plus will have no issues with a voltage sensing B2B.
I am typing the above on the assumption that you have Lithium Batteries as you seem to be saying your
Battery Master still works even without EHU or
Solar active?
Your forum name ... Lenny24v? you have a 24V system? both Main and Starter?